Small Spot/Mark (Separate Amplifier) Extremely thin beam ideal for detection of minute objects and marks. Order Omron Automation and Safety E3C-VS1G (ZND) at DigiKey. Check stock and pricing, view product specifications, and order online. Omron E3C-VS1G Photoelectric Sensor 10mm for E3C Amplifier: : Industrial & Scientific.

Author: Baramar Mikajora
Country: Suriname
Language: English (Spanish)
Genre: Life
Published (Last): 2 April 2011
Pages: 161
PDF File Size: 1.14 Mb
ePub File Size: 19.41 Mb
ISBN: 146-5-30246-911-9
Downloads: 8531
Price: Free* [*Free Regsitration Required]
Uploader: Dikora

Doing so may result in damage from burning and fire, particularly if the liquid is flammable. Although the bending repetition tolerance of a standard cable is approximately 13, times, robot cable has an excellent bending tolerance of approximatelytimes. If the connector is not connected securely, the connector may be disconnected by vibration or the proper degree of protection of the Sensor may not be maintained.

Refer to the values in the above table to check bend-resistant performance under actual working conditions. If not grounded, switching noise in the power supply may cause malfunction. Organic solvents will dissolve the surface. Any exceptions to this rule are indicated in Safety Precautions in individual product information. Do not use pliers, otherwise the connector may be damaged.

As a general rule, wire the Sensor in a separate system, use an independent metal conduit, or use shielded cable. Separate Sensors to distance where interference does not occur. This may weaken performance.

Precautions for Safe Use To ensure safety, always observe the following precautions. Doing so may cause explosion or burning.

OMRON E3C-VS1G Photoelectric sensor

Be sure to read Safety Precautions on page 4. They are rather values from samples taken from production lots, and are provided for reference as guidelines.

Typical measures are as given in the following table. Insert a capacitor e. In no event shall responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.

Omron E3c-vs1g E3CVS1G Photoelectric Sensor Switch

The axis from the center of the lens to the center of the beam for the Emitter and the axis from the center of the lens to the center of the reception area for the Receiver. Close mounting of Sensors is possible by alternating the Emitters with the Receivers in a zigzag fashion up to e33c-vs1g Sensors.

TOP Related Posts  ANGELAI IR DEMONAI KNYGA PDF

Please know and observe all prohibitions of use applicable to the products.

This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: Type of noise Noise intrusion path and countermeasure Before countermeasure Noise enters from the noise source through the frame metal. Secure the connector cover by hand.

Mutual Interference Mutual interference is a state where an output is unstable because the Sensors are affected by light from the adjacent Sensors. Separate the noise source and oomron Sensor to a distance where noise does not affect operation. Countermeasure Concept Use a Sensor with the interference prevention function. Typical examples include the minimum sensing object, engineering data, step height detection data, and selection list for specifications.

Omron E3c-vs1g E3CVS1G Photoelectric Sensor Switch | eBay

Exceptions are indicated in Safety Precautions in individual product information. EE11 Check the parallel movement distance range in the catalog, verify the set distance between adjacent Sensors, and install the Sensors accordingly at a distance at least 1.

Be sure to connect or disconnect the connector after turning Ec-vs1g the Sensor. Cable Tensile Strength When wiring the cable, do not subject the cable to a tension greater than that indicated in the following table.

Power line Work Required for Unconnected Leads E3c–vs1g leads for self-diagnosis outputs or other special functions should be cut and wrapped with insulating tape to prevent contact with other terminals. Separation from High Voltage Wiring Method Do not lay the cables for the Sensor together with high-voltage lines or power lines.

This is because the Sensors may affect each other and cause output chattering even if separated by more than the Sensor sensing distance. Ec-vs1g, if the workpieces are close to the Photoelectric Sensors, light from the adjacent Emitter may be received and cause the Sensor to change to the incident light state.

TOP Related Posts  BENIHANA NUTRITION FACTS PDF

For the E3S-C, the optical axis and the mechanical axis are the same, so the optical axis can be easily adjusted by aligning the mechanical axis. To maintain the fiber characteristics, make ommron that the lock is released before removing the fibers. Do not use it for such purposes. M8 and M12 Connectors? It is our practice to change model numbers when published ratings or features are changed, or when e3c-va1g Systems, machines, and equipment that could present a risk to life or property.

Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. The axis perpendicular to the center of the lens. The lens, case, and fiber covering are made of plastic, so this setup cannot be used if there is a possibility of contact with solvents that will corrode or degrade e. If Sensors are mounted in opposite each other, slant the Sensors as shown in the following diagram.

Do not subject a shielded cable or coaxial cable to tension. Cable diameter Less than 4 mm 4 mm or greater Tensile strength 30 N max. For bending-resistant cable, see Attachment to Moving Parts on page C Fiber insertion mark Fiber 9mm 2 Removing Fibers Open the protective cover, lift up the lock lever, and pull out the fibers.

If copying or transmitting this catalog to another, please copy or transmit it in its entirety. When in doubt, special model numbers may be assigned to? Precautions for Correct Use Do not use the product in atmospheres or environments that exceed product ratings. Power Supply Types An unsmoothed full-wave or half-wave rectifying power supply cannot be used.